Power usage effectiveness (PUE) is a widely-used metric that measures the efficiency of a data center. It is calculated by dividing the total amount of power consumed by the data center (including both IT and non-IT loads such as cooling and lighting) by the power consumed by the IT equipment. The resulting number is the PUE value. A PUE of 1.0 indicates that all of the power used by the data center is being used for IT equipment, while a PUE of 2.0 means that half of the power is being used for IT and the other half is being used for things like cooling and lighting. A lower PUE value indicates a more efficient data center, as it means that a larger proportion of the power consumed is being used for actual computing, rather than being wasted on non-IT loads.
However, some critics argue that PUE is not a true reflection of data center effectiveness. One concern is that the metric does not take into account the actual workload of the data center, only the power consumed. This means that a data center with a low PUE could still be performing poorly if it is not able to handle the demands placed on it, even if it is using power efficiently.
Another issue is that PUE does not consider the carbon emissions associated with the power used by the data center. While a data center with a low PUE may be using power efficiently, it could still be contributing significantly to greenhouse gas emissions if it relies on fossil fuels for its power.
In recent years, there has been a growing recognition of the need for more comprehensive measures of data center efficiency. One such measure is data center infrastructure efficiency (DCIE), which is expressed as a percentage and is calculated by dividing IT equipment power by total facility power.
DCiE = IT Equipment Power/Total Facility Power x 100%
Another measure that has gained attention is carbon usage effectiveness (CUE). CUE takes into account not just the power used by a data center, but also the carbon emissions associated with that power. This allows companies to not only track their energy usage, but also their impact on the environment.
There are also several other measures of data center efficiency that are worth considering, such as water usage effectiveness (WUE) and energy reuse effectiveness (ERE). WUE measures the amount of water used by a data center, while ERE measures the extent to which waste heat from a data center is captured and reused for other purposes.
Despite these limitations, PUE is still widely used as a measure of data center efficiency, and many organizations have made significant efforts to improve their PUE values. However, it is important to recognize that PUE should not be the only metric used to evaluate data center effectiveness, and that other factors such as workload, performance, and carbon emissions should also be considered.
As the demand for data continues to grow, it is becoming increasingly important for data centers to operate as efficiently as possible. By considering measures beyond PUE, companies can get a more complete picture of their data center’s efficiency and identify opportunities for improvement.